AEM-Electromagnetic Flowmeter for DN15~DN3000 Features and uses
★ Independence: The measurement is not affected by changes in liquid density,
viscosity, temperature, pressure and conductivity;
★ Energy saving and low fault: no moving and blocking parts in the measuring
tube, no blockage, no loss;
★ Widely used: conductive liquid, containing fiber, solid particles,
suspended liquid;
★ Easy installation: low requirements for straight pipe section (first 5D
after 2D);
★ Protection IP68, IP66: DN15~ DN1200, intrinsic immersion structure;
★ High intelligence: backlit LCD display, high integration, double isolation,
parameter setting, menu operation. Chinese display, memory function, reliable
programming, password lock and access, small signal cutting, non-linear
correction, two-way measurement;
★ SMT technology: intelligent self-test and self-diagnosis function, upper
and lower limit alarm, excitation alarm, air traffic control alarm;
★ SMART excitation: low power consumption, zero stability, no drift, reliable
operation;
★ Multiple output: current output (4~20) mA current, frequency
(1~5000)Hz,RS485/Modbus, HART;
★ Lining and electrode: lining and electrode materials have a variety of
choices, suitable for different media;
★ Ultra-low EMJ switching power supply: large power supply range, good
anti-interference performance;
Main Technical Datum
Accuracy:0.5%,1.0%
Repeatability:Not exceeding 1/3 othe absolute maximum of allowable error
Working condition |
Sensor |
Convertor |
|
Ambient temperature |
Separated type |
(-20~70)℃ |
(-20~55)℃ |
Monomorph |
(-20~+55)℃ |
||
Relative humidity |
Separated type |
(5~95)% |
( 5~90) % |
Monomorph |
(5~90)% |
Mechanical vibration: frequency (10~55Hz) amplitude 0.20mm
Environmental electromagnetic field :≤300A/m
Medium temperature: related to the lining material, – body type ≤+80℃, take
the lowest value of both
Nominal pressure: (0.6~42.0)MPa;
Fluid conductivity :≥5u/cm;
The battery power supply meter must be at least 20 u S/cm;
Power supply :24DC10VA, (85~265)V AC10VA,3.6V lithium battery;
Output signal :4~20mA current, frequency 1~5000Hz,RS485/modbus, HART;
Electrode material :316L stainless steel, Hastelloy, Chin, tantalum, lead
carbide, tungsten carbide, Monel;
Lining material: polytetrafluoroethylene, rubber, F46, PVC, polyurethane;
Flange material: carbon steel, can special order other materials.
Measuring catheter :1Cr18Ni9Ti
Explosion-proof class :ExdbebiallCT4/T5Gb
Flange standard :PN6~PN63 GB/T 9119-2010 RF
Class600~Class2500 GB/T 9115-2010 RJ